Step 4: Checking Sensors & Redeploying
If sampling spans >30 days (or the amount of time the sensor is estimated to record), replace batteries and SD cards at each check.
Stopping a Deploymentβ
-
If the sensor is actively recording the red light will be flashing and if the sensor is sleeping a green light will be flashing. If there are no LEDs flashing then the batteries are likely dead. Either way, switch to USB/Off.
-
Replace batteries and SD card with fresh ones.
Resetting Time in the Fieldβ
Familiarize yourself with the LED flashing patterns to ensure your redeployment is successful.
-
Switch to Custom β If the LEDs show solid red + flashing green it means the date/time is not set.
-
Hold smartphone with Chime App near the microphone.
You may need to hold the phone very close to the sensor, especially if soundscape is loud.
-
Tap Play Chime.
-
Once red LED turns off and green LED flashes intermittently, the time has been successfully set.
Intro Recording & Restartβ
-
Switch to Default and Record audio notes:
βThis is [name] on [date] at [time]. Site: [SPID]. Sensor name: [sensor_name] Additional notesβ¦β
Ex. "This is Abram Fleishman on 8 Dec 2025 at 12:10 PM. I am at Site 17 32.95332 N, -111.45922 W. I am deploying Sensor A01 at the edge of a forest with tall trees to the west and a field to the east. There is a goose nest 3 m to the SE of the sensor. "
-
Switch to USB/Off for 5 seconds.
- Red LED will flash 1β4 times indicating battery level.
-
Switch to Custom to to resume scheduled operation.
-
Replace sensor in the same spot and orientation and record check time on datasheet.